International Trade

Roysroy 

Diesel generator set_453 models_16~2500KW_FCS
    Publish time 2023-09-26 20:20    

Engine: Cummins/MTU/Mitsubishi/Weichai/Yuchai/Shangchai/Googol;

Generators: Stamford/Marathon/Leroysomer;

 

Brief Introduction to Diesel Generator Set

16~ 2500 KW | 453 Models


We can provide an overall solution for the generator set. Please contact our company for specific project team.

 

Application scope

Applied in data centers, power plants, mobile construction, mining, cogeneration, oil and gas, auxiliary power sources, basic and high backup applications.

 

 

Standard

The product meets the national standard GB/T2820.5 standard requirements.

 

Power Description

Continuous power: refers to the power that can be continuously used according to the rated load without time limit. Calibrate the engine for no overload capacity based on continuous power.

 

Common power: refers to the power that can be used instead of commercial power grids; The commonly used power can be divided into two types based on usage conditions.

1. Common power for unlimited operation

Engines calibrated according to commonly used power can be effectively used with variable load and no time limit. Within every 250 hours of operation, the average variable load cannot exceed 70% of the calibrated common power.

Within a year, the entire operating time of 100% common power shall not exceed 500 hours.

Within a 12 hour operating cycle, there is a 1 hour effective overload capacity of 10%. Within a year, the operating time of 10% overload shall not exceed 25 hours.

2. Common power for limited time operation

Engines calibrated according to commonly used power can operate indefinitely for constant load purposes. For example, in situations where low power is used and output power is limited. On the premise that the power will never exceed the commonly used power calibration, it is recommended to operate on the grid for less than 750 hours within one year.

 

Backup power: refers to the instantaneous maximum power of the backup power supply. When used at standby power, the engine has no overload capacity. Cannot be connected to the power grid for use.

 

The engine used for standby power shall be used at an average load rate of 80%, and shall not exceed 200 hours per year. The time used at the backup point shall not exceed 25 hours per year.

 

 

 

Altitude and ambient temperature

The rated power of a diesel generator set refers to the power at an altitude of no more than 1000 meters and an ambient temperature of less than 40 degrees Celsius.

If the altitude exceeds 1000 meters or the ambient temperature exceeds 40 degrees Celsius, please contact the factory to confirm the selection.

 







Appearance type I: open shelf

 

Features

Compact structure, easy to lift and transport.

Wide power coverage (6-3120KVA), which can meet the different needs of customers.

Equipped with well-known brand engines and generators to ensure strong power.

Equipped with a comprehensive intelligent control system, achieving protection of the unit and simple operation.

Long design life, suitable for various application scenarios.

Rich selection functions, including parallel systems, heating systems, high-temperature water tanks, etc.





 

Appearance type II: Silent box


Features

Low noise, compact overall structure.

The surface of the speaker is sprayed with plastic, suitable for various weather and climate conditions.

The structure of the silent speaker is reasonable, rainproof and noise proof.

Each unit is equipped with a base oil tank, and customers can choose a large capacity oil tank according to their actual situation.

There are dedicated lifting holes for easy lifting and installation.

Each machine undergoes strict factory testing to ensure excellent operation and stable performance of the product.


Standard configuration of silent box

Control panel_ Emergency stop button_ Waterproof adhesive strip_ Base oil tank_ Outlet_ Efficient flame retardant sound-absorbing cotton_ Refueling port_ Sewage outlet_ Outdoor full spray plastic box_ Door lock_ High strength hinge


Silent box options

Large capacity base oil tank_ Configuration under special weather/working conditions_ Bottom forklift hole_ Multiple box color options_ Ultra quiet design








Appearance Type III: Container











Appearance type IV: Four-wheel/two-wheel small trailer







Control system

 

Adantages

Selecting the SmarGen single machine operation module can provide monitoring and protection functions for the generator set.

The control module can display information such as generator set voltage, unit frequency, unit operating time, battery voltage, etc; It can provide functions such as over frequency protection, over voltage protection, low oil pressure protection, high water temperature protection, emergency shutdown, and alarm for the generator set.

The manufacturer has long-term cooperation with companies such as SmarGen, Deep-sea, and DEIF to select appropriate control modules for customers based on different application scenarios.



ATS automatic switching cabinet

Function: Switch between the main power supply and emergency power supply under unmanned operation.

Working principle: When the mains power is cut off and the voltage exceeds the normal voltage, ATS will automatically start the emergency generator set, and then switch the load electricity from the mains power to the generator set, which will supply power to the load of the generator set.

When the external power supply returns to normal, ATS will automatically switch the load electricity from the generator set to the external power supply, and then the generator set will stop working.


Parallel system

Adopting well-known brand parallel control modules to meet various customer needs.

Features:

Scalable: When the user's load increases, the system can be expanded by adding one or more generator sets.

Automation: Sequential startup of units, automatic adjustment of active and reactive power distribution, and automatic balancing of the operating time of each generator unit.

Reliability: Multiple generator sets are connected to a power grid, providing stable voltage and frequency supply, and can withstand the impact of significant load changes.

Economy: According to the size of user load, an appropriate number of low-power generator units can be invested to reduce the waste of fuel and oil caused by the small load operation of high-power units.

















453 Configuations | 16~2500 KW

 



Chongqing Cummins Engine | Stamford Generator | 1-40 items | 200-800 KW, 29-34 items: container type







Chongqing Cummins Engine | Stamford Generator | 41-80 items | 900-1100 KW, 42-46, 57-60 items: container type

Dongfeng Cummins Engine | Stamford Generator | 1-27 items | 16-350 KW







Dongfeng Cummins Engine | Stamford Generator | 28~54 items | 20~400 KW

MTU engine | 1-13 items | 520-2500 KW, 5-13 items: container type, 1-11 items: Stamford generator, 12-13 items: Marathon generator

Mitsubishi engine | Stamford generator | 1-10 items | 540-1900 KW, 3-10 items: container type










MHI engine | Stamford generator | 1-9 items | 540-1800 KW, 3-9 items: container type

Weichai Engine | 1-65 items | 16-2400 KW, 52-65 items: container type, 1-62 items: Stamford generator, 63-65 items: Marathon generator








Yuchai Engine | 1-81 items | 18-2400 KW, 69-81 items: container type, 1-79 items: Stamford generator, 80-81 items: Marathon generator







Shangchai Engine | Stamford Generator | 1-47 items | 12-728 KW

Shangchai Engine | Stamford Generator | 1-39 items | 36-1000 KW






Googol Engine | 1-55 items | 300-2500 KW, 1-8 items, 34-55 items: container type, 1-52 items: Stamford generator, 53-55 items: Marathon generator